Avanos Corflo 8Fr Nasogastric/Nasointestinal Feeding Tube 91cm With Stylet and ENFIT Connectors (40-9368)

AVA_40-9368_1_P

$47.52

Tax included. Shipping calculated at checkout.

Quantity
Packaging:

CORFLO Nasogastric/Nasointestinal Feeding Tube with Stylet with ENFit Connector is uniquely designed for delivering enteral nutrition. Each package comes with a variety of features that provide consistent performance and convenience, including an anti-clog bolus, centimeter markings, and a water activated lubricated tip and internal lumen.Multiple Choices for Clinician Convenience With multiple packages from which to choose, clinicians can choose whether or not they want ENFit, Universal, and Anti-IV proximal connectors. Similarly, our polyurethane CORFLO NG/NI tubes are available in various lengths and French sizes. Avanos Medical, a leader in the enteral feeding market, offers a wide variety of innovative, high-quality enteral feeding tubes and accessories designed for delivering enteral nutrition.

 

  • Weighted/Non-Weighted
  • With and without stylet
  • ENFit, Universal, and Anti-IV proximal connectors
  • Anti-clog bolus
  • CM Markings
  • MRI conditional once stylet is removed
  • Flow-Through Stylet
  • Radiopaque
  • Water Activated Lubricated Tip & Internal Lumen (stylet tubes only)

About CORFLO Nasogastric/Nasointestinal Feeding Tube with ENFit Connector

The AVANOS CORFLO Nasogastric/Nasointestinal Feeding Tube is a medical grade polyurethane feeding tube that has been specifically designed for patient comfort and safety during tube insertion and use. It is intended for use in patients who require intermittent or continuous tube feedings via the nasogastric or nasointestinal pathway.

Tube Capped (Fig. 6)

  • Feed Port
  • Auxiliary Port

Tube Connected (Fig.7)

  • Administration Set
  • Syringe

Features

  • Distinctive YELLOW tube design
  • Exit ports:
  • Anti-clog bolus
  • Bolus
  • ENFit design employed for reducing the risk of tubing misconnections.
  • ENFit satisfies the ISO Standard (80369-3) for small bore enteral devices.
  • Water-activated C-19* lubricant on tube tip
  • Dual port to maintain closed system
  • For YELLOW feeding tubes Radiopacity: 20% barium tube, 40% barium tip

Ability to Connect to Non-Enteral Medical Devices

The ENFit connectors were designed to prevent misconnections between enteral devices and other devices used in various medical applications. However, the design of the ENFit connector cannot overcome all chances of misconnection. The following connector types are potential misconnections for the ENFit connector (feeding/ medication access port) of this enteral feeding tube:

  • Suction ports on Endotracheal Suction Systems
  • Respiratory circuit filtration connectors
  • Oxygen inlet connectors for Resuscitation Devices
  • Baxter IV Solution Bag ports (such as NaCl, Ringers Solution, etc.)
  • Sample ports on drainage bags
  • Peritoneal Dialysis connectors
  • Cones & sockets of ISO 5356-1:2004 & ISO 5356-2:2004
  • Temperature sensor connectors & mating ports of ISO 8185:2007
  • Oxygen nipples as defined in EN 13544-2:2002

CORFLO NG/NI feeding tubes have satisfied biocompatibility testing as a device for long-term use per ISO 10993-1.

Note: Placement and use of any feeding tube may result in patient discomfort.

Avanos - Indications for Use

The AVANOS CORFLO Feeding Tube is intended for use in those patients who require intermittent or continuous tube feedings via the nasogastric or nasoenteric route.

MRI Safety Information

Non-clinical testing demonstrated that the weighted CORFLO Enteral Feeding Tubes are MR Conditional. A patient with this device can be scanned safely immediately after placement under the following conditions:

Static magnetic field of 3-Tesla or less
Spatial gradient magnetic field of 720-Gauss/cm or less
MR system reported whole body averaged SAR of 3.0-W/kg
(i.e., associated with a calorimetry measured value of 2.8- W/kg)

Under the conditions described above using a transmit/receive RF body coil the CORFLO Enteral Feeding Tube produced the Highest temperature change of +1.5 degree celcius during MRI performed for 15-min in the 3-Tesla (3-Tesla/ 128-MHz, Excite, Software G3.0-052B, General Electric Healthcare, Milwaukee, WI) MR system.

Artifact Information: MR image quality may be compromised if the area of interest is relatively close to the position of the CORFLO Enteral Feeding Tube. Therefore, optimization of MR imaging parameters to compensate for the presence of this device may be necessary.

 

Link To Other Sizes and Models 

 

Avanos Corflo Nasogastric/Nasointestinal Feeding Tube
Anti-Clog With Enfit Connector Anti-Clog With Enfit Connector Smooth Shape Bolus With Stylet Anti-Clog Pill Shaped Bolus With Enfit Connector Controllers With Enfit Connector Controller With Enfit Connector Smooth Shape Bolus Controller With Enfit Connector Pill Shape Bolus
5Fr 6Fr 8Fr, 10Fr 8Fr, 10Fr, 12Fr 8Fr, 10Fr 8Fr, 10Fr
6Fr 8Fr        
8Fr 10Fr        
10Fr 12Fr        
12Fr        

 

 